Injection method for homogeneous masonry
More InformationsFilter
Filter
m_50215
SELECT DISTINCT shop_view_active_item.* FROM shop_item_has_category INNER JOIN shop_view_active_item ON ( shop_view_active_item.company = shop_item_has_category.company AND shop_view_active_item.shop_code = shop_item_has_category.shop_code AND shop_view_active_item.language_code = shop_item_has_category.language_code AND ( shop_item_has_category.item_no = shop_view_active_item.item_no ) ) WHERE (shop_item_has_category.category_line_no = 97500 OR shop_item_has_category.category_line_no = 97500 ) AND shop_view_active_item.language_code = 'ENU' AND shop_view_active_item.company = 'DESOI' AND shop_view_active_item.shop_code = 'B2B' AND shop_item_has_category.company = 'DESOI' AND shop_item_has_category.shop_code = 'B2B' AND shop_item_has_category.language_code = 'ENU' AND shop_item_has_category.category_shop_code = 'B2B'
9 Show Variants
Log in
The entered access data are not correct. Please try again.
Add Item to
Shopping Basket Add all selected Items
to Shopping Basket Remove Item from Shopping Basket Add Item to Favorites Remove Item from Favorites Stock Outage
Make a Preorder Insufficient Stock Item well stocked Article in delivery This item is part of a current campain
Shopping Basket Add all selected Items
to Shopping Basket Remove Item from Shopping Basket Add Item to Favorites Remove Item from Favorites Stock Outage
Make a Preorder Insufficient Stock Item well stocked Article in delivery This item is part of a current campain
Injection method for homogeneous masonry
The selected injection material is injected into the component by means of continuous pressure (3 – 5 bar), which is adjusted to the component, via bore packers. It is important that the injection material is distributed relatively evenly in order to ensure that an effective zone is formed. The injection pressure should therefore be maintained over a longer period of time (e. g. several minutes per packer), depending on the component conditions.
Horizontal sealing / Horizontal barriers
Subsequent injection against capillary ascending moisture
open PDF
Subsequent injection against capillary ascending moisture
open PDF
Filling materials and execution for the injection of
Injection into Homogenous Masonry
- Injection of the micro emulsion (step 2)
- Creation of the horizontal seal above the pressure and water line
Filling Materials and Process of Injecting Homogenous Brick Masonry with Low Alkalinity and Moisture Content above 80 %
- Injection of the micro emulsion (Wet-on-Wet Technique – step 2) – Creation of the horizontal seal
- Injection of the activator to initiate hardening of the micro emulsion (step 3)
Filling Materials
- Silicone and micro emulsion
- Silification solution
- Siloxane-based injection fluid
- Acrylate gel
Advantages
- Strengthening and stabilization of masonry walls in the injection area
- Less equipment and fittings required, ie. drill bits and packers
- Less work required per linear meter
Advantages – Acrylate Gel
- Works as soon as the chemical reaction finishes
Types of Packers
- Bore packers (steel)
- Drive-in packers (polymer)
1. Mark the positions of holes every 10 to 12.5 cm (4 to 5 inches) for a single row of drill holes. For a multi-row chain of drill holes a linear separation of approximately 8 cm (3.3 inches) is recommended. The optimal distance between drill holes depends on the absorptive capacity of the masonry. Then drill your holes, insert at least one horizontal joint and remove the dust.
2. Hammer in the lamella packer with the mounting tool.
One advantage of using the parts with the numbers 31710 and 37753 is that it is not necessary to remove the packer after injecting. The packer can remain in the masonry so that it is possible to plaster the wall immediately.
2. Hammer in the lamella packer with the mounting tool.
One advantage of using the parts with the numbers 31710 and 37753 is that it is not necessary to remove the packer after injecting. The packer can remain in the masonry so that it is possible to plaster the wall immediately.
3. Injecting and closing up
• Start the injection pump in accordance with instruction manual
• Inject the holes with a pressure of between 2 and 5 bar, depending on masonry
• Knock off the packers or remove them
• Seal drill holes
• Start the injection pump in accordance with instruction manual
• Inject the holes with a pressure of between 2 and 5 bar, depending on masonry
• Knock off the packers or remove them
• Seal drill holes
Wir brauchen Ihr Einverständnis!
Wir benutzen Drittanbieter, um Videoinhalte einzubinden. Diese können persönliche Daten über Ihre Aktivitäten sammeln. Bitte beachten Sie die Details und geben Sie Ihre Einwilligung.
Wir benutzen Drittanbieter, um Videoinhalte einzubinden. Diese können persönliche Daten über Ihre Aktivitäten sammeln. Bitte beachten Sie die Details und geben Sie Ihre Einwilligung.
Mehr Informationen
Externe Medien Akzeptieren
Wir brauchen Ihr Einverständnis!
Wir benutzen Drittanbieter, um Videoinhalte einzubinden. Diese können persönliche Daten über Ihre Aktivitäten sammeln. Bitte beachten Sie die Details und geben Sie Ihre Einwilligung.
Wir benutzen Drittanbieter, um Videoinhalte einzubinden. Diese können persönliche Daten über Ihre Aktivitäten sammeln. Bitte beachten Sie die Details und geben Sie Ihre Einwilligung.
Mehr Informationen
Externe Medien Akzeptieren